EasyManuals Logo

Davis Instruments Vantage Pro2 Console Manual

Default Icon
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #52 background imageLoading...
Page #52 background image
49
Appendix B
Specifications
See complete specifications for your Vantage Pro2 Station at our website:
www.davisnet.com.
Console
Console Operating Temperature . . . . . . . .+14° to +140°F (-10° to +60°C)
Display Temperature . . . . . . . . . . . . . . . . .+32° to +140°F (0° to +60°C)
Non-operating Temperature. . . . . . . . . . . .-5° to +158°F (-20° to +70°C)
Console Current Draw . . . . . . . . . . . . . . .Wireless: 0.9 mA average, 30 mA
peak, (add 80 mA for display lamps,
add 0.125 mA for each transmitter
station received by console) at 4 to 6
VDC
Cabled: 10 mA (average), 15 mA
(peak) (+80 mA for illuminated dis-
play) at 4 to 6 VDC
Power Adapter. . . . . . . . . . . . . . . . . . . . . . 5 VDC, 900 mA
Battery Backup . . . . . . . . . . . . . . . . . . . . .3 C-cells
Battery Life (no AC power) . . . . . . . . . . . . Wireless: up to 9 months; (Cabled: 1
month (approximately)
Connectors . . . . . . . . . . . . . . . . . . . . . . . . Modular RJ-11
Housing Material . . . . . . . . . . . . . . . . . . . . UV-resistant ABS plastic
Console Display Type . . . . . . . . . . . . . . . . LCD Transflective
Display Backlight . . . . . . . . . . . . . . . . . . . . LEDs
Dimensions:
Console (with antenna). . . . . . . . . . . . 10.375" x 6.125" x 1.5" (264 mm x
156 mm x 38 mm)
Console (no antenna) . . . . . . . . . . . . .9.625" x 6.125" x 1.5" (244 mm x
156 mm x 38 mm)
Display. . . . . . . . . . . . . . . . . . . . . . . . 5.94" x 3.375" (151 mm x 86 mm)
Weight (with batteries) . . . . . . . . . . . .1.88 lbs. (.85 kg)
Wireless Communication Specifications
Transmit/Receive Frequency . . . . . . . . . . . US Models: 902 - 928 MHz
Overseas Models:868.0 -868.6 MHz
ID Codes Available . . . . . . . . . . . . . . . . . . 8
Output Power. . . . . . . . . . . . . . . . . . . . . . . 902 - 928 MHz FHSS: FCC-certified
low power, less than 8 mW, no li-
cense required
868.0 -868.6 MHz: CE-certified, less
than 8 mW, no license required
Range
Line of Sight. . . . . . . . . . . . . . . . . . . . up to 1000 feet (120 m)
Through Walls . . . . . . . . . . . . . . . . . . 200 to 400 feet (75 to 150 m)
07395.234 Manual VP2 console Book.book Page 49 Wednesday, November 17, 2004 3:57 PM

Other manuals for Davis Instruments Vantage Pro2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Davis Instruments Vantage Pro2 and is the answer not in the manual?

Davis Instruments Vantage Pro2 Specifications

General IconGeneral
Update Interval2.5 seconds
Wind Direction Resolution
Wind Direction Range0 to 360°
Rain CollectorSelf-emptying tipping bucket
UV Index Range0 to 16
Solar Radiation Range0 to 1800 W/m²
Console DisplayLCD with backlight
Wireless Transmission Range1000 feet (300 meters) line of sight
Temperature Range-40 to 150 °F (-40 to 65 °C)
Humidity Range1 to 100%
Barometric Pressure Range16.00 to 32.50 inHg (540 to 1100 hPa)
Wind Speed Range0 to 200 mph (0 to 322 km/h)
Rain Collector Size0.01 inch (0.2 mm) resolution
Rain Measurement Accuracy±4% at rates up to 2 in/hr (50 mm/hr)
Power SupplySolar-powered with battery backup
Console Power SupplyAC adapter or 3 C batteries

Related product manuals