EasyManuals Logo

Davis Instruments Vantage Pro2 Console Manual

Default Icon
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #55 background imageLoading...
Page #55 background image
Weather Data Specifications
52
Solar Radiation Solar sensor 1 W/m
2
0 to 1800 W/m
2
5% of full scale
Inside
Temperature
Included in Console 0.1°F; 0.1°C
+32° to +140°F; 0 to
+60°C
1°F; 0.5°C
Outside
Temperature
***
ISS, Temp Station
or Temp Hum
Station
0.1°F; 0.1°C
-40° to +150°F;
-40° to +65°C
1°F; 0.5°C
Extra Temperature
ISS, Temp Station,
Temp Hum Station,
Leaf Soil Station or
Soil Station
1°F; 1°C
-40° to +150°F
-40° to +65°C
1°F (0.5°C)
Heat Index
ISS or Temp/Hum
Station
1°F; 1°C
-40° to +135°F;
-40° to +57° C
3°F (1.5°C)
Temp-Hum-Sun-
Wind index
(THSW)
ISS & Solar
Radiation
1°F; 1°C
-90° to +135°F;
-68° to +64° C
4°F (2°C)
Time
Included in Console
1 min 24 hours 8 sec/mon
Date 1 day month/day 8 sec/mon
UV Index
UV Radiation
0.1 Index 0 to 16 5% of full scale
UV Dose
0.1 MED < 20,
1 MED > 20
0 to 199 MEDs 5%
Wind Direction
Anemometer
1° 0 to 360° 7°
Compass Rose 22.5° 16 compass pts 0.3 compass pt
Wind Speed (large
cups)
1 mph; 1 kt; 0.5 m/s;
1 km/h
2 to 150 mph;
2 to 130 kts
3 to 241 km/h,
1 to 68 m/s
greater of
2 mph/kts;
1 m/s; 3 km/h
or 5%
Wind Speed (small
cups)
1 mph; 1 kt; 0.5 m/s;
1 km/h
3 to 175 mph;
3 to 150 kts
1.5 to 79 m/s
5 to 282 km/h
greater of
3mph; 3 kts;
1 m/s; 5km/h
or 5%
Wind Chill ISS 1°F; 1°C
-120° to +130°F
-84° to +54°C
2°F;1°C
***
Outside temperature accuracy is based on the temperature sensor itself and not on the sensor and the passive
shielding together. The solar radiation induced error for standard ration shield: +4°F (2°C) at solar noon; for fan
aspirated radiation shield: +0.6°F (0.3°C) at solar noon (insolation = 1040 W/m
2
, avg. wind speed 2 mph (1
m/s), reference: RM Young Model 43408 Fan-Aspirated Radiation Shield).
Weather Data Specifications
Variable Required Sensors Resolution Range
Nominal Accuracy
(+/-)
07395.234 Manual VP2 console Book.book Page 52 Wednesday, November 17, 2004 3:57 PM

Other manuals for Davis Instruments Vantage Pro2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Davis Instruments Vantage Pro2 and is the answer not in the manual?

Davis Instruments Vantage Pro2 Specifications

General IconGeneral
Update Interval2.5 seconds
Wind Direction Resolution
Wind Direction Range0 to 360°
Rain CollectorSelf-emptying tipping bucket
UV Index Range0 to 16
Solar Radiation Range0 to 1800 W/m²
Console DisplayLCD with backlight
Wireless Transmission Range1000 feet (300 meters) line of sight
Temperature Range-40 to 150 °F (-40 to 65 °C)
Humidity Range1 to 100%
Barometric Pressure Range16.00 to 32.50 inHg (540 to 1100 hPa)
Wind Speed Range0 to 200 mph (0 to 322 km/h)
Rain Collector Size0.01 inch (0.2 mm) resolution
Rain Measurement Accuracy±4% at rates up to 2 in/hr (50 mm/hr)
Power SupplySolar-powered with battery backup
Console Power SupplyAC adapter or 3 C batteries

Related product manuals