Alarm Mode
33
Time
The time alarm is a standard “alarm clock” alarm. It sounds for one minute
at the set time. Make sure you choose AM or PM, if you’re in 12-hour
mode.
UV Dose
The UV dose alarm sounds when the accumulated UV dose has exceeded
the dose you set. The UV dose alarm does not arm unless the initial UV
dose for the day has been reset. Once the UV dose alarm value is set, clear
the accumulated UV dose. See “Clearing Weather Variables” on page 29.
Setting Alarms
1. Press ALARM to enter the Alarm Mode to view or set the high alarm
thresholds. The screen displays the current high alarm thresholds. The
ALARM and HIGHS icons also appear.
2. Press the right and left arrows to select one of the variables displayed on
the screen or use the console keys to select any weather variable. Also,
press HI/LOW to display the toggle between the high and low alarm
threshold settings.
3. Press 2ND then press ALARM to activate the currently selected weather
variable.
4. Press the right and left arrows to select digits in the threshold value.
5. Press the up and down arrows to change the digits value up and down.
6. Press DONE to finish changing the alarm setting.
7. Repeat steps 3 through 6 to change additional alarm settings.
8. Press DONE to exit Alarm Mode.
Setting the Time Alarm
1. Press ALARM to enter alarm mode.
The ALARM and HIGHS icons appear.
2. Press 2ND, then press TIME, then press 2ND again, and then press
ALARM.
The time field begins blinking.
3. Press the left and right arrows to select hours, minutes, or AM/PM.
4. Press up and down arrows to change the digit’s value up and down.
5. Press DONE to exit Alarm Mode.
Clearing Alarm Settings
1. Press ALARM to enter alarm mode.
The ALARM and HIGHS icons appear.
2. Select the alarm setting you wish to clear.
3. Press 2ND, then press and hold CLEAR until the setting changes to all
dashes.
07395.234 Manual VP2 console Book.book Page 33 Wednesday, November 17, 2004 3:57 PM

Other manuals for Davis Instruments Vantage Pro2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Davis Instruments Vantage Pro2 and is the answer not in the manual?

Davis Instruments Vantage Pro2 Specifications

General IconGeneral
Update Interval2.5 seconds
Wind Direction Resolution
Wind Direction Range0 to 360°
Rain CollectorSelf-emptying tipping bucket
UV Index Range0 to 16
Solar Radiation Range0 to 1800 W/m²
Console DisplayLCD with backlight
Wireless Transmission Range1000 feet (300 meters) line of sight
Temperature Range-40 to 150 °F (-40 to 65 °C)
Humidity Range1 to 100%
Barometric Pressure Range16.00 to 32.50 inHg (540 to 1100 hPa)
Wind Speed Range0 to 200 mph (0 to 322 km/h)
Rain Collector Size0.01 inch (0.2 mm) resolution
Rain Measurement Accuracy±4% at rates up to 2 in/hr (50 mm/hr)
Power SupplySolar-powered with battery backup
Console Power SupplyAC adapter or 3 C batteries

Related product manuals