Troubleshooting, Repair, & Warranty
Page 46 Vantage Pro Manual
•Technical Support Fax: (510) 670-0589
• Automated Fax-Back Service: (510) 293-3548
Automated service for copies of product Spec Sheets. Available 24 hours
a day, seven days a week.
• Davis Instruments Web Site: http://www.davisnet.com.
Check here under ”support” for troubleshooting FAQs, the latest
updates, PDFs of all Davis product manuals, as well as application notes
and technical documents .
•Technical support email: support@davisnet.com
Problem Solution PG.
D
ISPLAY
Display is blank
Unit is not receiving power. Check to be
sure the power adapter has not come
unplugged from the console or outlet.
Battery may be run down or old. Replace.
11
11
Display shows a series of
dashes in place of func-
tion reading
ISS not plugged in (Cabled Vantage Pro).
See ISS manual.
Sensors not transmitting (Wireless Van-
tage Pro). See ISS (or other transmitter)
manual.
Console not receiving (Wireless). See
“Reception Problems” on page 49 below.
A reading has exceeded the limits indi-
cated in the specifications table.
Calibration numbers may be causing read-
ings to exceed display limits. Check cali-
bration number and adjust if necessary.
14,
50
59
33
Display is sluggish or
computer does not work
at low temperatures
The console, LCD display, and internal
components may not work below 32º F
(0ºC). Use the External Temperature sen-
sor in low-temperature locations and keep
the Vantage Pro console in a warmer loca-
tion.
14
Display “locks up”
If the console “locks up”, remove all
power (including battery backup) and
then restore power. If “lock ups” occur fre-
quently in an AC-powered console, plug
the AC power-adapter into a surge sup-
pressor.
11