7 / 18
TRG8084
Antenna structure: Universal blow-up antenna
Measuring range:0.08m~10m/0.08m~30m/
0.3m~60m/0.3m~120m
Power supply: 12~28V DC
Accuracy: ±1mm/±1mm
±3mm/±5mm
Beam angle: 3°
Output signal: 4~20mA+HART
RS485+Modbus RTU
Ambient temperature: -40℃~+70℃
IP rating: IP67
Housing material: Aluminum alloy
Process temperature: -40~200℃
Process pressure: -0.1~0.3 MPa
TRG8085
Antenna structure: High temperature and high voltage antenna
Measuring range:0.08m~10m/0.08m~30m/
0.3m~60m/0.3m~120m
Power supply: 12~28V DC
Accuracy: ±1mm/±1mm
±3mm/±5mm
Beam angle: 3°
Output signal: 4~20mA+HART
RS485+Modbus RTU
Ambient temperature: -40℃~+70℃
IP rating: IP67
Housing material: Aluminum alloy
Process temperature:-40~1000℃
Process pressure: -0.1~10 MPa
3.2 Explosion-proof Signs
Pass national level explosion-proof certification:
Intrinsically safe: Ex ia IIC T1~T5/T6 Ga; Ex iaD 20 T85°C
Intrinsically safe and explosion-proof composite type: Ex d ia [ia Ga]IIC T1~T5/T6 Gb; Ex tD
A21 T105℃/T85℃
3.3 Implementation Standards
TRG808X 80GHz Radar Level Meter Implementation Standards:
JB/T 13252-2017 Microwave (Radar) Level Meters
4 Outline Dimension Diagram
The connection flange is used in conjunction with the site flange, the user is required to provide
the flange standard, if the order requires a special size, the actual size shall prevail - Figure 1 to
Figure 5