5.1.2 Check the quantity and material of each part against the packing list.
5.2 Check Content
5.2.1 Check whether the appearance of the instrument is defective or damaged.
6 Installation
6.1 Installation Tools
Spanners, flange gaskets and flange bolts for process joints.
6.2 Installation Requirements
Installation Position
When mounting, take care to keep the instrument at least 200 mm away from the vessel wall
Figure 7
- Reference surface
- Central container or axis of symmetry
Figure 7 Installation Position Diagram
For conical vessels with a flat tank top, the best mounting position for the instrument is in the
center of the top of the capacity so that the bottom of the vessel can be measured - Figure. 8