 WARNING  To ensure an appropriate level of electrical safety always keep very low tension cables 
(controls, electric lock, aerial and auxiliary circuits power supply) separate from (min 4 mm if not in-
sulated, 1 mm through insulation) 230V power supply cables. To keep them apart put cables inside a 
tubing tray and fasten them with clamps near the terminal board. Make sure cables are not damaged 
or worn off during installation.
 WARNING  Any installation, maintenance or repair operation on the whole system must be carried 
out exclusively by qualified personnel.  All these operations must be performed only after disconnecting 
the power supply, and operating in strict compliance with the electrical standards and regulations in 
force in the nation of installation.
 WARNING  Refer to “F3 Installation” when installing the control panel. Execute only drilling holes 
foreseen by the constructor to allow for wire passage, use indicated cable clamps only. Failure to comply 
with these instructions may jeopardize the level of electrical safety.
 WARNING  Before the learning of the operators stroke:
• Select the type of operators: with encoder (P034=0 and J8=J10=pos. A); without encoder (P034=1 
and J8=J10=pos. B).
• Select the number of operators used: 2 operators (P029=0); 1 operator (P029=1).
• Make sure that eventual safety devices, photocells and limit switches are connected and working cor-
rectly. Their presence is automatically detected by the control panel during the learning.
 WARNING   Wrong assessment of impact forces may cause serious damage to people, animal and 
things.  DEA System reminds all personnel that the installer must ascertain that these impact forces, measu-
red according to  EN 12245 prescriptions, are actually below the limits indicated by  EN12453 regulation.
 WARNING  Any external safety device installed in order to conform to the limits set for impact forces 
must comply with EN12978.
 WARNING  Using spare parts not indicated by DEA System and/or incorrect re-assembly may en-
danger people, animals and property, and may also cause malfunctioning of the product: always use 
parts provided by DEA System and follow assembly instructions.
 WARNING  Disposal of packaging materials (such as plastic, card board, etc.) must be done accor-
ding to regulations in force locally.  Do not leave plastic bags and polystyrene within the reach of children.
 3  MODELS AND CONTENTS OF THE PACKAGE
The control board 202RR can be supplied together with DEA System gate operators for swing gates ope-
rated by one or two operators 230V ~ or it is supplied individually as spare part to be used only with DEA 
System gate operators as mentioned above.  
     4  PRODUCT DESCRIPTION 
202RR control board has been designed for the control of swing gates operated by one or two 
230V ~ It is extremely versatile, easy to install and fully complies with European regulations concerning 
electromagnetic compatibility and electric safety.
Main features of the product:
1.  Setting all parameters by 3 keys and a 4-digit display;
2.  Facility to actuate operators with or without encoder;
3.  Facility to fine tune motor speed during its complete stroke. It preserves motor torque even at very low 
speed (operators with encoder);
4.  Slow down with fixed speed (operators without encoder);
5.  Facility to separately adjust the slow down endurance for two operators;
6.  Internal anti-crash safety device whose sensitivity can be adjusted (according to a 70-level scale) separately 
for both operating directions (opening/closing differentiated speed only for operators provided of encoder);
7.  Inputs to connect both normal and powered external safety devices (mechanical ribs or photocell bar-
riers), with the possibility to run a self-test before each operation;
8.  Built-in 433,92MHz radio receiver for both HCS and HT12E coding offering the possibility to search 
and delete each transmitter separately.