EN-17
4  Downloading/uploading data memory
4.1  Downloading data to an external memory unit (DOWNLOAD)
1.  Scroll down the parameters with 
 and   keys until you visualize P011;
2. Press the  key, the display visualizes the word “ ” fl ashing;
3. Press the
 again and continue pressing it for 5 sec (if you release it before this period, the procedure is stopped);
4. Release the
 key as soon as the word “ ” stops fl ashing;
All the control panel confi gurations (TYPE, parameters, remotes, operators stroke, etc..) are saved in the external memory unit;
Warning: If there is any data in the external memory, during the memory download they will be overwritten.
5. At the end of the operation display returns to P011.
4.2  Uploading data from an external memory unit (UPLOAD)
1.  Scroll down the parameters with 
 and   keys until you visualize P012;
2. Press the  key, the display visualizes the word “ ” fl ashing;
3. Press the  again and continue pressing for 5 sec (if you release it before this period, the procedure is stopped);
4. Release the  key as soon as the word “ ” stops fl ashing;
All the control panel confi gurations (TYPE, parameters, remotes, operators stroke, etc..) contained in the external memory unit are 
uploaded in the connected control panel;
5. At the end of the operation display returns to P012.
WARNING If you are not connected to any external storage units or if the connecting cable is disconnected during the data transfer 
operation, the display will visualize  , then the control unit is entirely reset and the display shows the word “TYPE” fl ashing. 
Refer to the instruction of the external memory card to restore the operation of the control panel.
5  Inputs confi guration
Where the installation requires different commands and / or additional to 
the standard ones described by plan, you can confi gure each input for the 
operation desired (eg START, PHOTOS, STOP, etc ...).
1. Scroll down the parameters with the 
 and   to see that corresponding
to the desired one:
● P017=for INPUT 1;
● P018=for INPUT 2;
● P019=for INPUT 3;
● P020=for INPUT 4;
● P021=for INPUT 5;
● P022=for INPUT 6;
2. Confi rm by pressing on the
 key to get access to the parameter (eg. 
P018);
3. Scroll down with the
 and  , keys to set the value corresponding to 
the desired operation (refer to table “Input Confi guration parameters” on 
page EN-20);
4. Confi rm by pressing on the
 key (display shows again P018).
5. Execute the new connection to the input just reconfi gured.
6  Programming complete
WARNING At the end of the programming procedure, use the buttons   and   until the appearance of the symbol “----”, the operator 
is now ready again for new manoeuvres.