EN-18
8  MESSAGES SHOWN ON THE DISPLAY
WORKING STATUS MESSAGES
Mess. Description
Gate is closed
Gate is opened
Opening under way
Closing under way
While in step-by-step mode, the control board awaits further instructions after a start command
Stop input intervened or an obstacle is detected with limited inversion duration (P055 > 0 or P056 > 0)
Board in BOOT-MODE: Indicates that the fi rmware is corrupted or updating. To restore the fi rmware, use the DEAinstaller APP and make sure 
NET-NODE is corrected to the correct port.
Warning: When updating the fi rmware, all data in the board memory (settings and radio commands) are lost. Make sure you have backed 
up the memory to be restore data after the update.
Reset current position: The control unit has just been turned on after a power failure, or the gate has exceeded the maximum number (80) 
of inversions allowed without ever getting to the closing stroke, or the maximum number (15) of consecutive operations allowed of the anti- 
crushing device.
Once the control unit has been reset and open command given the gate will start moving at slow speed, until it reaches end of travel.
ERROR MESSAGES
Mess. Description Possible solutions
Error position: The reset position procedure is not suc-
cessful. The control panel is awaiting commands.
- Make sure there are no specifi c frictions and / or obstacles during the run;
- Give a start pulse to initiate a position reset procedure;
- Verify that the operation is completed successfully, manually helping the run, if ne-
cessary;
- Adjust power and speed settings if necessary.
Board programming attempted when a NET-NODE 
device is connected.
Turn off power, disconnect the NET-NODE from the communication port and turn back 
on;
External photocells and/or safety devices are activated 
or out of order.
- Make sure that all safety devices and/or photocells installed are working properly.
Possible fault/overheating in the control unit’s power 
circuit.
Turn off power for several minutes and turn back on. Give a start command: if the 
message is repeated, replace the control unit.
Time-out operators run: The engine/s exceeded the 
maximum operating time (4min) without ever stopping.
- Give a start pulse to start the position reset procedure;
- Ensure that this operation is successful.
Time-out obstacle detection: With anti-crushing sensor 
disabled, was still detected the presence of an obsta-
cle that prevents movement of the leaf for a period of 
10 seconds more.
- Make sure there are no specifi c frictions and / or obstacles during the run;
- Give a start pulse to initiate a position reset procedure;
- Verify that the operation is completed successfully.
Operators mouvement not detected.
- Make sure that operators and encoders connections are well done.
- Check that jumpers J5 and J9 are well positioned as shown on the electric wiring.
- If this error appears again, replace the control panel.
No/interrupted communication with remote memory 
board (also NET-EXP or NET-NODE).
- Check that the connecting cable of the external memory card is connected properly. 
- If you are performing a data transfer operation (DOWNLOAD / UPLOAD), make sure
that it is not interrupted (eg by unplugging the card before the end of the operation). 
Please note: the interruption of an UPLOAD, also involves a total RESET of the control 
unit.
Possible fault/overheating in the control unit’s power 
circuit.
Turn off power for several minutes and turn back on. Give a start command: if the 
message is repeated, replace the control unit.
Possible malfunction in the control unit’s power circuit 
or in the encoder circuit.
Check the wiring of the encoder and the motor. Shut the power supply off and on again. 
Give a start command: if the message is repeated, perform the following checks.
- Enter P003 and move the door using the + and - buttons. 
- If the door moves at maximum speed and the display shows Err7, replace the motor’s 
encoder card.
- If the motor still remains stationary, replace the control unit.
Sensitive regulation parameters were edited via 
DEAinstaller APP without running motor stroke learning 
at the end of the operation.
Run motor stroke learning (P003) fi rst to be able to run any other operation.
NET-NODE connected to the incorrect communication 
port.
Connect NET-NODE to the correct port according to that indicated in the control unit 
diagram.