In Example B–3, SET HOST/DUP/DSSI 0 PARAMS is entered to start the DUP
server for the ISE at node 0 of the embedded DSSI bus. In Example B–4,
SET HOST/DUP/UQSSP/DISK 0 PARAMS is entered to start the DUP server for
the ISE at controller 0 of a KFQSA-based DSSI bus.
Example B–3: Starting the DUP Driver Utility (Embedded DSSI)
>>>SET HOST/DUP/DSSI 0 PARAMS
Starting DUP server...
Copyright (c) 1991 Digital Equipment Corporation
PARAMS>
Example B–4: Starting the DUP Driver Utility (KFQSA-Based DSSI)
>>>SET HOST/DUP/UQSSP/DISK 0 PARAMS
Starting DUP server...
Copyright (c) 1991 Digital Equipment Corporation
PARAMS>
B.3.2 Setting Allocation Class
After entering the DUP driver utility for a specified device, you can examine
and set the allocation class for the device as follows:
1. At the PARAMS> prompt, enter SHOW ALLCLASS to check the allocation
class of the ISE to which you are currently connected.
2. Enter SET ALLCLASS 2 (or enter the allocation class you desire).
3. Enter SHOW ALLCLASS to verify the new allocation class.
B–8 VAX 4000 Model 200 (BA430) Operation