WHE 2.24 / WHE 2.24 FF
Wall-hung gas boilers
User Guide
300011777-001-C
EN

Questions and Answers

  • P
    petersoncrystalJul 30, 2025
    What to do if the water level is too low in my DeDietrich WHE 2.24?
    • M
      Mr. Aaron MillerJul 31, 2025
      If the water level and/or pressure are too low in your DeDietrich Boiler, first, ensure water is circulating properly by checking the water pressure in the heating circuit, and that flow and return valves, as well as valves and radiators, are open. Then, top up the heating circuit with water and visually inspect for any water leaks.
  • D
    dustin36Aug 4, 2025
    How to fix air pressure error due to insufficient draught in DeDietrich WHE 2.24 Boiler?
    • A
      annette62Aug 4, 2025
      To address an air pressure error due to insufficient draught in your DeDietrich Boiler, inspect the fresh air inlet and flue gas discharge ducts (or the forced flue). Then, press the Reset button for 2 seconds. If the problem continues, further assistance is needed.
  • R
    rcalderonAug 8, 2025
    What causes flue gas temperature sensor error in DeDietrich WHE 2.24?
    • D
      daybrittanyAug 8, 2025
      A flue gas temperature sensor error in your DeDietrich Boiler may be caused by insufficient draught. Check for adequate draw on the chimney connection. The boiler is in safety shutdown until the flue gas temperature sensor is again operational, so wait 15 minutes. If the problem persists, further assistance is needed.
  • K
    Kelly MontgomeryAug 13, 2025
    What to do if the temperature sensor circuit is broken in DeDietrich Boiler?
    • V
      Valerie NelsonAug 13, 2025
      If the temperature sensor circuit in your DeDietrich Boiler has been broken or short-circuited, first ensure that the water is circulating properly. Check the water pressure in the heating circuit and verify that the flow and return valves, as well as the valves and radiators, are open. If the problem persists, further assistance is needed.
  • V
    Veronica ThompsonAug 17, 2025
    What to do if no flame is detected after 5 attempts in DeDietrich Boiler?
    • M
      Mark GreerAug 17, 2025
      If your DeDietrich Boiler fails to detect a flame after 5 attempts, press the Reset button for 2 seconds. If the issue continues, further assistance is needed.
  • D
    Doris HaleAug 21, 2025
    How to fix communication error between safety control box and PCB in DeDietrich Boiler?
    • D
      deborah67Aug 21, 2025
      To fix a communication error between the safety control box and the PCB in your DeDietrich Boiler, check the cable connecting the safety control box and the PCB. Then, press the Reset button for 2 seconds. If the problem persists, further assistance is needed.
  • J
    Jason MillerAug 26, 2025
    Why is there no current to my DeDietrich WHE 2.24 Boiler?
    • C
      Christine SantosAug 26, 2025
      If there's no current to your DeDietrich Boiler, check the electrical connections.

Summary

Introduction to the Boiler

Safety and Information Symbols

Explains warning symbols for safety and specific information relevant to user comfort and operation.

General Liability Information

Details manufacturer, installer, and user liabilities and responsibilities for proper boiler operation and maintenance.

Safety Instructions and Recommendations

Critical Safety Warnings

Critical safety warnings related to fire, gas, burns, and equipment damage during operation and installation.

Operational Recommendations

Provides essential recommendations for safe operation, installation, and maintenance practices for the boiler.

Product Description

Boiler Model Features

Overview of the boiler's features, including modulation range, efficiency, and key components for both models.

Control Panel and Operation

Control Panel Overview

Explains the layout and function of the boiler's control panel, including indicator lights and buttons.

Indicator Light Meanings

Defines the meaning of indicator lights for various operational states like standby, heating, and errors.

Changing Appliance Settings

Guides users on how to adjust key settings like heating temperature and domestic hot water temperature.

Heating Temperature Adjustment

Instructions for setting the summer/winter mode and the desired heating circuit temperature.

DHW Temperature Adjustment

Instructions for setting the desired domestic hot water (DHW) temperature using the thermostat.

Boiler Shutdown Procedures

Details the procedures for safely stopping the boiler, including switching off, antifreeze, and long-term shutdown.

Boiler Restart Procedure

Guides users through the steps for safely restarting the boiler after shutdown, including initial commissioning.

Checking and Maintenance

Annual Maintenance Tasks

Lists essential checks and maintenance tasks that should be performed at least once a year for optimal performance.

Troubleshooting and Error Resolution

Error Message Indicators

Details how the boiler's indicator lights signal specific error messages and communication faults.

Common Incidents and Solutions

Provides common operational issues, such as burner not working or cold radiators, with suggested solutions.

Technical Specifications

Boiler Performance Data

Presents detailed technical specifications for the WHE 2.24 and WHE 2.24 FF models, including power, efficiency, and dimensions.

Warranty Information

Warranty Terms and Conditions

Explains the warranty terms, conditions, exclusions, and responsibilities of the manufacturer, installer, and user.

DeDietrich WHE 2.24 Specifications

General IconGeneral
CategoryBoiler
Maximum Working Pressure3 bar
Fuel TypeNatural gas
Nominal Heat Output (kW)24 kW
EfficiencyUp to 109%
Gas Connection3/4"
TypeCondensing
DHW ProductionInstantaneous