7.4 Analogue SIN/COS azimuth indicators
Input type Input 1 Input 2 Pointer position (scale)
FWD design:
EM=12**
Pointer CW*
AFT design: EM=6**
Pointer CW*
4 to 20 mA 12 mA 4 mA
0 
0 to 10 V 5 V 0 V
 to 0 to 10 V 0 V  V
4 to 20 mA 4 mA 12 mA
 
0 to 10 V
0 V 5 V
 to 0 to 10 V  V 0 V
4 to 20 mA 12 mA 20 mA
180 
0 to 10 V 5 V 10 V
 to 0 to 10 V 0 V 10 V
4 to 20 mA 20 mA 12 mA
 
0 to 10 V 10 V 5 V
 to 0 to 10 V 10 V 0 V
* Note: Make sure that the pointer rotation matches other indicators/transmitters in the system  etc.).
** Note: EM can be changed 180 degrees (from 6  or 12  by turning the rear side adjustment potentiometer A.
Installation and commissioning guide 4189350024O EN