Automatic shut-off takes too long or there is continuous flow
(Fig. K):
• Clean the inside of the delay case using a clean, dry cloth;
and clean the calibrated groove with a non-metallic, sharp point.
• Check that the lip seal and seat are in good condition.
• AB cartridge: remember to replace the spring .
Dripping or a constant trickle (Fig. K):
• Clean the seat or replace if damaged.
• AB cartridge: remember to replace the spring .
Beware
: do not grease the inside of the mechanism.
Mixer: regularly check (as often as necessary) the temperature
selector and the mixer's two internal seats on which the mixing key
turns. Replace as necessary.
NB: Check that the seals between wall plate and the wall and
between the wall plate and the mixer/tap/valve are watertight
at least once a year, and more often if necessary. Replace as necessary.
MAINTENANCE AND CLEANING
• Cleaning chrome: do not use abrasive, chlorine or any other
acid-based cleaning products. Clean with mild soapy water using
a cloth or a sponge.
• Frost protection: drain the pipes and operate the mixer/tap/valve
several times to drain any remaining water.
• Ö
M
d
• M
• A
o
(
(
T
~
• V
v
• M
(
(
F
• F
A
M
•
M
• A
f
• B
• A
d
After Sales Care and Technical Support:
For the UK market only: Tel. 0 1491 821 821 email: technical@delabie.co.uk
The installation guide is available on: www.delabie.co.uk
For all other markets: Tel. +33 (0)3 22 60 22 74 email: sav@delabie.fr
The installation guide is available on: www.delabie.com
Fig. K: = standard cartridge = AB cartridge
Parts of the cartridge:
= seat
= valve holder
= calibrated groove
= delay case
= lip seal
= spring
NT 745 indI FR-EN-DE-PL-NL-ES-PT-RU_Mise en page 1