Preliminary
941322_VMS Instruction Book 2006.pdf2009-09-07
No. Name Range Default Description/optionsNo. Name Range Default Description/options
0 = no acidic cleaning0 = no acidic cleaning
1 = one alkaline, one acidic cleaning1 = one alkaline, one acidic cleaning
2 = two alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning
3 = etc.3 = etc.
Maintenance an calibration
The following points are important to sustain
correct dosing of etergents. Note that
these two tasks should be performed by an
authorised DeLaval service engineer.
• The tubes in the peristaltic pumps should
be replaced at least two times a year.
• The dosing volume (P6-P8) of the
detergent pumps should be checked
every third month. The dosing capacity
(P32-P34) may need to be adjusted.
Starting cleaning or rinsing
from the touch screen
Note: Any ongoing backflush process must
first be finished before cleaning or rinsing
can be started.
1. Ensure that the milking station is in
manual mode.
2. Remove any cow that might be in the
milking station.
After treatment window
Note: Both gates should be closed to
prevent a cow from entering before the
system cleaning has been started. Closing
and opening gates is done in the Stall
control window.
3. Press the tab After Treatment on the
touch screen to display the After treatment
window.
4. In the After treatment window, press the
Cleaning and Rinsing button. This will open
the Cleaning and rinsing window.
n Connect the equipment into an outlet on a
circuit different from that to which the receiver
is connected.
n Consult the dealer or an experienced radio/
TV technician for help.
This device complies with part 15 of the FCC
Rules. Operation is subject to the following two
conditions: (1) This device may not cause harm-
ful interference, and (2) this device must accept
any interference received, including interference
that may cause undesired operation.
Note! Changes or modifications not expressly
approved by the party responsible for compliance
could void the user's authority to operate the
equipment.
7.2 ISED Compliance Statement
This device contains license-exempt transmit-
ter(s)/receiver(s) that comply with Innovation,
Science and Economic Developments Canada's
License-exempt RSS standard(s). Operation is
subject to the following two conditions: (1) this
device may not cause interference, and (2) this
device must accept any interference, including
interference that may cause undesired operation
of the device.
Note! Changes or modifications not expressly
approved by the party responsible for compliance
could void the user's authority to operate the
equipment.
8 Type plate
A Product name
B Part number
C Serial number
D Input: voltage, maximum current
E CE marking
F Crossed-out wheeled bin with a hori-
zontal bar, see
Ä
Chapter 2 "Disposal
of waste electrical and electronic
equipment" on page 39.
G Manufacturer's address
Precision Analytics 100
Serial No: 2003009
Part No: 60091513
Heard Navigator
Input : 24 VDC, max 3 A
C US
CM
5002525
And CSA C22.2#61010-1-12:2012 Ed.3
Confoms toUL 61010-1:2012 Ed.3
ANATEL
04053-21-04018
A
E
B
C
D
GF
276554
Fig. 1: The Herd Navigator 100 type plate.