Preliminary
941322_VMS Instruction Book 2006.pdf2009-09-07
No. Name Range Default Description/optionsNo. Name Range Default Description/options
0 = no acidic cleaning0 = no acidic cleaning
1 = one alkaline, one acidic cleaning1 = one alkaline, one acidic cleaning
2 = two alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning
3 = etc.3 = etc.
Maintenance an calibration
The following points are important to sustain
correct dosing of etergents. Note that
these two tasks should be performed by an
authorised DeLaval service engineer.
The tubes in the peristaltic pumps should
be replaced at least two times a year.
The dosing volume (P6-P8) of the
detergent pumps should be checked
every third month. The dosing capacity
(P32-P34) may need to be adjusted.
Starting cleaning or rinsing
from the touch screen
Note: Any ongoing backflush process must
first be finished before cleaning or rinsing
can be started.
1. Ensure that the milking station is in
manual mode.
2. Remove any cow that might be in the
milking station.
After treatment window
Note: Both gates should be closed to
prevent a cow from entering before the
system cleaning has been started. Closing
and opening gates is done in the Stall
control window.
3. Press the tab After Treatment on the
touch screen to display the After treatment
window.
4. In the After treatment window, press the
Cleaning and Rinsing button. This will open
the Cleaning and rinsing window.
EU Declaration of Conformity
Name of product: DeLaval Herd Navigator™ precision analytics 100
Type/model: HN100
Report No. D0000092398
The product complies with requirements of the following directives:
Radio equipment directive RED 2014/53/EU
Restriction of the use of certain hazardous substances (RoHS) - 2011/65/EU
Harmonized standards which have been used or parts thereof:
EN 300 330 V2.1.0
EN 301 489-1 V2.2.0
EN 301 489-3 V2.1.1
EN 50581
Other technical standards and specifications used:
EN 61000-6-2: 2005 +AC:2005
EN 61000-6-3:2007
EN 61010-1:2010
EN 61010-2-081:2015
Fulfills RoHS by design and purchase control
This declaration of conformity is issued under the sole responsibility of the manufacturer.
Tumba 2019-09-23 Signed:
Name: Magnus Berg
Position: Executive Vice President
Department: Product Management & Develop-
ment
© DeLaval 2021.
2021-05-10, Version 3 5 (44) 2800008901

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DeLaval Herd Navigator precision analytics 100 and is the answer not in the manual?

DeLaval Herd Navigator precision analytics 100 Specifications

General IconGeneral
BrandDeLaval
ModelHerd Navigator precision analytics 100
CategoryAnalytical Instruments
LanguageEnglish