Part Number: 9291457 6/19 11
Section 2 Installation
Model
Total
Weight
Unit
Weight
Total
Drawer
Capacity
Maximum
Cooking
Equipment
Weight
Low-Profile Freezer Base
F2660CP,
F2660P
1500lbs
(680kg)
418lbs
(190kg)
75lbs
(34kg)
1007lbs
(457kg)
F2694CP,
F2694P
1500lbs
(680kg)
505lbs
(229kg)
150lbs
(68kg)
845lbs
(383kg)
Low-Profile Refrigerator Base
F2936CP,
F2936P
1000lbs
(454kg)
374lbs
(170kg)
150lbs
(68kg)
476lbs
(216kg)
F2952CP,
F2952P,
F2952-E
1000lbs
(454kg)
398lbs
(181kg)
150lbs
(68kg)
452lbs
(205kg)
F2956CP,
F2956P,
F2956-E
1000lbs
(454kg)
405lbs
(184kg)
150lbs
(68kg)
445lbs
(202kg)
F2960CP,
F2960P,
F2960-E
1500lbs
(680kg)
464lbs
(211kg)
300lbs
(136kg)
736lbs
(334kg)
F2962CP,
F2962P,
F2962-E
1500lbs
(680kg)
479lbs
(217kg)
300lbs
(136kg)
721lbs
(327kg)
F2973CP,
F2973P,
F2973-E
1500lbs
(680kg)
535lbs
(243kg)
300lbs
(136kg)
665lbs
(302kg)
F2975CP,
F2975P,
F2975-E
1500lbs
(680kg)
540lbs
(245kg)
300lbs
(136kg)
660lbs
(299kg)
F2978CP,
F2978P,
F2978-E
1500lbs
(680kg)
589lbs
(267kg)
300lbs
(136kg)
611lbs
(277kg)
F2980CP,
F2980P,
F2980-E
1500lbs
(680kg)
600lbs
(272kg)
300lbs
(136kg)
600lbs
(272kg)
F2987CP,
F2987P,
F2987-E
1500lbs
(680kg)
672lbs
(305kg)
450lbs
(204kg)
378lbs
(171kg)
F2996CP,
F2996P,
F2996-E
1500lbs
(680kg)
725lbs
(329kg)
450lbs
(204kg)
325lbs
(147kg)
F2999CP,
F2999P,
F2999-E
1500lbs
(680kg)
725lbs
(329kg)
450lbs
(204kg)
325lbs
(147kg)
F29110CP,
F29110P,
F29110-E
1800lbs
(816kg)
766lbs
(347kg)
450lbs
(204kg)
584lbs
(265kg)
Electrical Service
DANGER
Check all wiring connections, including factory
terminals, before operation. Connections can become
loose during shipment and installation.
n
Warning
This appliance must be grounded and all field wiring
must conform to all applicable local and national
codes. Refer to rating plate for proper voltage. It is the
responsibility of the end user to provide the disconnect
means to satisfy the authority having jurisdiction.
Plug units with R290 refrigerant into a receptacle that is
a minimum of 14” (36cm) above the floor.
All electrical work, including wire routing and
grounding, must conform to local, state and national
electrical codes.
The equipment must be grounded.
A separate fuse/circuit breaker must be provided for
each unit.
The maximum allowable voltage variation is ±10% of
the rated voltage at equipment start-up (when the
electrical load is highest).
Check all green ground screws, cables and wire
connections to verify they are tight before start-up.
Ground Fault Circuit Interrupter
Ground Fault Circuit Interrupter (GFCI/GFI) protection is
a system that shuts down the electric circuit (opens it)
when it senses an unexpected loss of power, presumably
to ground. Manitowoc does not recommend the use of
GFCI/GFI circuit protection to energize our equipment.
If code requires the use of a GFCI/GFI then you must
follow the local code. The circuit must be dedicated, sized
properly and there must be a panel GFCI/GFI breaker. We
do not recommend the use of GFCI/GFI outlets to energize
our equipment as they are known for more intermittent
nuisance trips than panel breakers.
Notice
These appliances will operate within the marked rated
voltage range without adjustment.
Notice
This symbol indicates the location of the equipotential
bonding conductor connection.