Section 3 Operation
115 Volt Controls
The unit ON/OFF switch is located behind the louvered
panel.
The temperature 112ERC control display is located in
the nosing above the louvered panel.
F2660CP With Temperature Control in Nosing
AT START UP
1. At initial start-up or anytime power is disconnected,
then reconnected to the unit, the control will go into
defrost mode.
2. The control will enter a DEFROST mode and the display
will read dEF. The compressor and condenser fan as
well as the evaporator fan will remain off until this
initial defrost is complete. This initial defrost cycle may
take up to 35 minutes to complete.
3. The display will continue to read dEF for an additional
30 minutes while the cooling cycle cools the box to the
set temperature.
4. Then the digital thermostat will display box
temperature.
5. The temperature control will cycle the compressor,
evaporator fan motor and condenser fan motor to
maintain box temperature at the control setting. For
more information see Evaporator Fan Operation on
page 16.
Defrost
The temperature control also monitors the evaporator
temperature and will turn off the compressor and
condenser fan motor when needed to allow accumulated
frost on the evaporator to clear. During this defrost cycle,
the digital temperature display will read dEF. After the
defrost cycle is complete, the temperature control will
return to a normal cooling cycle, but the display will
continue to read dEF until the evaporator returns to normal
cooling temperatures (up to 30 minutes).
The electronic temperature controller monitors evaporator
temperature and compressor run time to determine the
proper time for a positive defrost cycle. A defrost cycle
can occur as often as every 60 minutes under extremely
heavy usage. It can last a minimum of 2 minutes. When the
controller enters the defrost mode the compressor is shut
off and will remain off until the evaporator coil temperature
exceeds:
41°F (5°C) or the controller reaches a time limit of 75
minutes on a refrigerated unit.
55°F (13°C) or the controller reaches a time limit of 35
minutes on a freezer.