EasyManua.ls Logo

Dell EMC PowerEdge R750xs 60KKP - Page 65

Dell EMC PowerEdge R750xs 60KKP
154 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Figure 57. Cable routing - 8 x 2.5-inch NVMe drive backplane to the front PERC with cable riser 1A and BOSS S2
card
Table 20. Cable routing - 8 x 2.5-inch NVMe drive backplane to the front PERC with cable riser 1A and
BOSS S2 card
From To
BP_PWR_1 (Power connector on backplane) SIG_PWR_1 (Power connector on the PIB)
DST_PA1 (Signal connector on backplane) Connector on front PERC
DST_PB1 (Signal connector on backplane) Connector on front PERC
DST_PA2 (Signal connector on backplane) Connector on front PERC
DST_PB2 (Signal connector on backplane) Connector on front PERC
RISER_PWR_1 (Power connector on the riser) SIG_PWR_0 (Power connector for cabled riser on system
board)
RISER_DST_PB2 (Signal connector on riser) SL6_CPU2_PB3 (Signal connector on system board)
RISER_DST_PA2 (Signal connector on riser) SL5_CPU2_PA3 (Signal connector on system board)
Signal connector on riser SL7_CPU1_PA4 (Signal connector on riser)
Signal connector on riser SL8_CPU1_PB4 (Signal connector on riser)
Installing and removing system components 65

Table of Contents