2. Display the physical device (PD) information:
/opt/lsi/perccli/perccli /c0/eall/sall show
Output similar to the following is displayed:
3. Verify that all the devices have a virtual device created on them.
In the Drive Information output, the device state displayed as "Onln" in the
State column shows that the device has a virtual device created on it.
4. Display device group (DG) and virtual device (VD) information:
/opt/lsi/perccli/perccli /c0/vall show
Output similar to the following is displayed:
5. Verify that all the VDs are configured correctly.
The following values should appear in the display:
l
Cache = NRWTD (for SSDs)
Preparing Disks