10 Installing the Hardware
Environmental Parameters
Power Supply
Width 17 inches (432 mm) 17 inches (432 mm)
Depth 16.73 inches (425 mm) 16.73 inches (425 mm)
Chassis weight with
factory-installed
components
12 pounds (5.5 kg) 12 pounds (5.5 kg)
Rack clearance required Front: 5-inches (12.7 cm)
Rear: 5-inches (12.7 cm)
Front: 5-inches (12.7 cm)
Rear: 5-inches (12.7 cm)
Parameter S2410P S2410CP
Temperature 32° to 104°F (0° to 40°C)
-40° to 158°F (-20° to 70°C)
32° to 104°F (0° to 40°C)
-40° to 158°F (-20° to 70°C)
Thermal Dissipation
(Maximum Thermal
Output)
S2410P: 768.2 BTU/Hour S2410CP: 426.8 BTU/Hour
Maximum altitude No performance degradation
to 10,000 feet (3,048 meters)
No performance degradation
to 10,000 feet (3,048 meters)
Relative humidity Operating: 10 to 90% relative
humidity (RH) non-
condensing
Storage: 10 to 95% RH non-
condensing
Operating: 10 to 90% relative
humidity (RH) non-
condensing
Storage: 10 to 95% RH non-
condensing
Shock MIL-STD-810 MIL-STD-810
Vibration Telcordia GR-63-CORE Telcordia GR-63-CORE
ISO 7779 A-weighted
sound pressure level
S2410P: 61.5 dBA at 73.4°F
(23°C)
S2410CP: 61.5 dBA at 73.4°F
(23°C)
Parameter S2410P S2410CP
Nominal Input Voltage 100 - 240 VAC, 50/60 Hz,
auto-sensing
100 - 240 VAC, 50/60 Hz,
auto-sensing
Parameter S2410P S2410CP