EasyManua.ls Logo

Dell Latitude 9450 2-in-1 - System-Diagnostic Lights

Dell Latitude 9450 2-in-1
123 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
System-diagnostic lights
This section lists the system-diagnostic lights of your Latitude 9450 2-in-1.
Battery-status light
Indicates the power and battery-charge status.
Solid whitePower adapter is connected and the battery has more than 5 percent charge.
Amber—Computer is running on battery and the battery has less than 5 percent charge.
Off
Power adapter is connected and the battery is fully charged.
Computer is running on battery and the battery has more than 5 percent charge.
Computer is in sleep state, hibernation, or turned off.
The power and battery-status light blinks amber along with beep codes indicating failures.
For example, the power and battery-status light blinks amber two times followed by a pause, and then blinks white three times.
Followed by a pause. This 2,3 pattern continues until the computer is turned off indicating no memory or RAM is detected.
Table 45. System-diagnostic lights
Blinking pattern
Problem description Suggested resolutionAmber White
1 1 TPM detection failure
Replace the system board.
1 2 Unrecoverable SPI Flash
Failure
Replace the system board.
1 5 EC unable to program i-Fuse
Replace the system board.
1 6 Generic catch-all for
ungraceful EC code flow
errors
Disconnect all power source
(AC, battery, coin cell) and
drain flea power by pressing
and holding down the power
button for 3~5 seconds.
2 1 CPU failure
Run the Dell SupportAssist
or Dell Diagnostics tool.
If the problem persists,
replace the system board.
2 2 System board failure (included
BIOS corruption or ROM
error)
Flash latest BIOS version
If the problem persists,
replace the system board.
2 3 No memory or RAM detected
Confirm that the memory
module is installed
properly.
If the problem persists,
replace the memory
module.
2 4 Memory or RAM failure
Reset and swap memory
modules among the slots.
If the problem persists,
replace the memory
module.
2 5 Invalid memory installed
Reset and swap memory
modules among the slots.
If the problem persists,
replace the memory
module.
Troubleshooting 119