Upgrade Dell EMC Networking N1500 Series Switches
Page 2
Upgrade Dell EMC Networking N1500 Series Switches
The procedure given below to download firmware to an individual switch or a stack of switches.
Please do not interrupt switch operation during the downloading process as this may result in corruption of
flash memory. Do not power off a switch undergoing the upgrade process unless specifically directed to do so
by the instructions.
An annotated download example is shown following this section.
1. Back up your configuration.
2. Upgrade using telnet or SSH require default enable authentication method or enable password in current
configuration. If not configured follow steps below to configure an enable password:
console#configure
console(config)#enable password <password>
console(config)#exit
console#copy running-config startup-config
3. Download the 6.5.2.9 firmware image (N1500v6.5.2.9.stk) to the switch or stack master.
NOTE: Activate the image to use as the boot (active) image after the switch
resets. Images on the N1500 series switches are named active and backup.
4. Activate 6.5.2.9 firmware.
5. Reload the switch.
6. Update boot-code.
7. Reload the switch.
NOTE: A TFTP server must be on the network and the switch software
must be accessible to the TFTP server before attempting to download the
switch software by TFTP.
NOTE: The following TFTP server may be used if you do not have one:
http://tftpd32.jounin.net/tftpd32_download.html

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell N1548P and is the answer not in the manual?

Dell N1548P Specifications

General IconGeneral
ModelN1548P
Switching Capacity176 Gbps
Forwarding Rate131 Mpps
PoE Power Budget740 W
Power DeviceInternal power supply
Voltage RequiredAC 120/230 V (50/60 Hz)
Operating Temperature0 °C to 45 °C
Device TypeSwitch
Enclosure TypeRack-mountable
Ports48 x 10/100/1000
Uplink Ports4 x 10G SFP+
Routing ProtocolOSPF, RIP, VRRP
Remote Management ProtocolSNMP 1, Telnet, SSH, HTTP, HTTPS
FeaturesLayer 3 switching, IGMP snooping, Link Aggregation Control Protocol (LACP), Quality of Service (QoS)
Compliant StandardsIEEE 802.3, IEEE 802.3u, IEEE 802.3z, IEEE 802.1D, IEEE 802.1Q, IEEE 802.3ab, IEEE 802.1p, IEEE 802.3af, IEEE 802.3x, IEEE 802.3ad
Dimensions4.32 cm
Storage Temperature70 °C
Relative Humidity10 to 90% (non-condensing)
Jumbo Frame Support9216 bytes