EasyManua.ls Logo

Dell Networking S4810

Dell Networking S4810
17 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
16 SCG1000 | Dell Networking S4810 and Force10 S4810 Configuration Guide for EqualLogic SANs
5.8 Configure login credentials
FTOS(conf)#username admin privilege 15 password 0 yourpassword
FTOS(conf)#enable password level 15 0 yourpassword
5.9 Configuring switch ports
FTOS(conf)#interface range tengigabitethernet 0/0 47
FTOS(conf-if-range-te-0/0-47)#mtu 12000
FTOS(conf-if-range-te-0/0-47)#switchport
FTOS(conf-if-range-te-0/0-47)#spanning-tree rstp edge-port
FTOS(conf-if-range-te-0/0-47)#flowcontrol rx on tx off
FTOS(conf-if-range-te-0/0-47)#no shutdown
FTOS(conf-if-range-te-0/0-47)#exit
FTOS(conf)#interface range tengigabitethernet 1/0 47
FTOS(conf-if-range-te-1/0-47)#mtu 12000
FTOS(conf-if-range-te-1/0-47)#switchport
FTOS(conf-if-range-te-1/0-47)#spanning-tree rstp edge-port
FTOS(conf-if-range-te-1/0-47)#flowcontrol rx on tx off
FTOS(conf-if-range-te-1/0-47)#no shut
FTOS(conf-if-range-te-1/0-47)#exit
FTOS(conf)#protocol spanning-tree rstp
FTOS(conf-rstp)#no disable
FTOS(conf-rstp)#exit
FTOS(conf)#exit
5.10 Save configuration and reload
FTOS#copy running-config startup-config
Reload the stack to allow settings to take effect:
FTOS#reload
Note: The preceding procedure places all switch ports in the default VLAN. If you prefer to place ports in
a non-default VLAN, refer to the documentation for your switch.

Table of Contents

Other manuals for Dell Networking S4810

Related product manuals