Steps
1. Slide the hard drive into the hard-drive carrier.
2. Replace the two screws (6-32) to secure the hard drive to the hard-drive carrier.
3. Align the tabs on the hard-drive carrier with the slots on the chassis and snap the hard-drive carrier onto the disk-drive
cage.
4. Replace the two screws (6-32) to secure the hard drive carrier on the chassis.
5. Connect the data and power cables to the connectors on the hard drive.
Next steps
1. Install the side cover.
2. Follow the procedure in After working inside your computer.
Disk-drive cage
Removing the disk-drive cage
Prerequisites
1. Follow the procedure in Before working inside your computer.
2. Remove the side cover.
3. Remove the front bezel.
4. Remove the 2.5-inch hard drive if applicable.
5. Remove the 3.5-inch hard drive if applicable.
Removing and installing Customer Replaceable Units (CRUs)