Code Text Causes Corrective action
E1A15 SAS Cable B SAS cable B is missing or
bad.
Escalate for possible server
replacement.
E1A1D Control panel USB
cable not detected.
USB cable to the control
panel is missing or bad.
Reseat the cable. If the problem
persists, escalate for possible server
replacement.
E2010 No Memory No memory is installed in the
system.
Escalate for possible memory or
server replacement.
E2011 Mem Config Err Memory detected, but is not
configurable. Error detected
during memory configuration.
Escalate for possible server
replacement.
E2012 Unusable Memory Memory is configured, but
not usable. Memory
subsystem failure.
Escalate for possible memory or
server replacement.
E2013 Shadow BIOS Fail The system BIOS failed to
copy its flash image into
memory.
Escalate for possible memory or
server replacement.
E2014 CMOS Fail CMOS failure. CMOS RAM
not functioning properly.
Escalate for possible server
replacement.
E2015 DMA Controller DMA controller failure. Escalate for possible server
replacement.
E2016 Int Controller Interrupt controller failure. Escalate for possible server
replacement.
E2017 Timer Fail Timer refresh failure. Escalate for possible server
replacement.
E2018 Prog Timer Programmable interval timer
error.
Escalate for possible server
replacement.
E2019 Parity Error Parity error. Escalate for possible server
replacement.
E201A SIO Err SIO failure. Escalate for possible server
replacement.
E201B Kybd Controller Keyboard controller failure. Escalate for possible server
replacement.
E201C SMI Init System management
interrupt (SMI) initialization
failure.
Escalate for possible server
replacement.
E201D Shutdown Test BIOS shutdown test failure. Escalate for possible server
replacement.
E201E POST Mem Test BIOS POST memory test
failure.
Escalate for possible server
replacement.
E2020 CPU Config CPU configuration failure. Check for specific error messages.
Table continues…