EasyManua.ls Logo

Dell POWEREDGE R805 - Page 25

Dell POWEREDGE R805
200 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
About Your System 25
E1232 VDD 12V PS#
PwrGd
The specified power supply
has failed or has been
removed from the bay while
the system was on.
If removed, reinsert the
power supply into the bay
and reconnect to power.
For component failures,
see "Getting Help" on
page 175.
E123B LOM Mezz
PwrGd
Voltage regulator for the
LOM daughter card has
failed.
Recycle power to the
system or clear the SEL. If
the problem persists, see
"Getting Help" on
page 175.
E123C Planar LOM
PwrGd
Voltage regulator for the
integrated LOM has failed.
Recycle power to the
system or clear the SEL. If
the problem persists, see
"Getting Help" on
page 175.
E1310 RPM Fan ## RPM of specified cooling
fan is out of acceptable
operating range.
See "Troubleshooting
System Cooling
Problems" on page 149.
E1313 Fan
Redundancy
The system is no longer fan-
redundant. Another fan
failure will put the system at
risk of over-heating.
Check control panel LCD
for additional scrolling
messages. See
"Troubleshooting System
Cooling Problems" on
page 149.
Table 1-6. LCD Status Messages (continued)
Code Text Causes Corrective Actions

Table of Contents

Other manuals for Dell POWEREDGE R805