40 About Your System
PCIe Degraded
Link Width Error:
Embedded
device
Expected Link
Width is
n
Actual Link Width
is
n
Faulty system board or riser
board.
See "Getting Help" on
page 175.
PCIe Degraded
Link Width Error:
Integrated
device
Expected Link
Width is
n
Actual Link Width
is
n
The specified PCIe device is
faulty or improperly installed.
For a SAS controller
daughter card, reseat the card
in the dedicated PCIe
connector. See "Installing a
SAS Controller Daughter
Card" on page 84. If the
problem persists, see
"Getting Help" on page 175.
PCIe Degraded
Link Width Error:
Slot
n
Expected Link
Width is
n
Actual Link Width
is
n
Faulty or improperly installed
PCIe card in the specified
slot.
Reseat the PCIe card in the
specified slot number. See
"Expansion Cards" on
page 91. If the problem
persists, see "Getting Help"
on page 175.
PCIe Training
Error: Embedded
device
Faulty system board or riser
board.
See "Getting Help" on
page 175.
PCIe Training
Error:
Integrated
device
The specified PCIe device is
faulty or improperly installed.
For a SAS controller
daughter card, reseat the card
in the dedicated PCIe
connector. See "Installing a
SAS Controller Daughter
Card" on page 84. If the
problem persists, see
"Getting Help" on page 175.
Table 1-7. System Messages (continued)
Message Causes Corrective Actions