Expanded operating temperature
Table 29. Expanded operating temperature specications
Expanded operating temperature Specications
< 10% of annual operating hours 5°C to 40°C at 5% to 85% RH with 29°C dew point.
NOTE: Outside the standard operating temperature (10°C to
35°C), the system can operate continuously in temperatures as low
as 5°C and as high as 40°C.
For temperatures between 35°C and 40°C, de-rate maximum allowable dry
bulb temperature by 1°C per 175 m above 950 m (1°F per 319 ft).
< 1% of annual operating hours –5°C to 45°C at 5% to 90% RH with 29°C dew point.
NOTE: Outside the standard operating temperature (10°C to
35°C), the system can operate down to –5°C or up to 45°C for a
maximum of 1% of its annual operating hours.
For temperatures between 40°C and 45°C, de-rate maximum allowable
temperature by 1°C per 125 m above 950 m (1°F per 228 ft).
NOTE: When operating in the expanded temperature range, system performance may be impacted.
NOTE: When operating in the expanded temperature range, ambient temperature warnings maybe reported on the LCD panel and
in the System Event Log.
Video specications
Table 30. R940 video
specications
Resolution Refresh rate Horizontal frequency Pixel clock
1024 x 768 60 Hz 48.4 kHz 65.0 MHz
1280 x 800 60 Hz 49.7 kHz 83.5 MHz
1280 x 1024 60 Hz 64.0 kHz 108.0 MHz
1360 x 768 60 Hz 47.71 kHz 85.5 M
1440 x 900 60 Hz 55.9 kHz 106.5 MHz
1600 x 900 60 Hz (RB) 55.54 kHz 97.75 M
1600 x 1200 60 Hz 75.0 kHz 162.0 MHz
1680 x 1050 60 Hz (RB) 64.7 kHz 119.0 MHz
1920 x 1080 60 Hz 67.158 kHz 173.0 MHz
1920 x 1200 60 60 Hz 74.556 kHz 193.25 MHz
*RB-Reduced Blanking for Digital Displays requiring less blank time. This was introduced for Signal Integrity improvements by reducing Pixel
Clock rates for VGA-Analog input devices.
44
Appendix A. Additional specications