About Your System 23
Not a boot diskette The operating system is
trying to boot from a
diskette that does not have
a bootable operating system
installed on it.
Insert a diskette that has a
bootable operating system.
Option ROM Checksum
Error
PCI device BIOS (Option
ROM) checksum failure is
detected during shadowing.
Ensure that all appropriate
cables are securely
connected to the expansion
cards. If the problem
persists, see
"Troubleshooting
Expansion Cards" on
page 127.
PCIe Degraded Link
Width Error:
Embedded
Bus#
nn
/Dev#
nn
/Func
n
Expected Link Width
is
n
Actual Link Width
is
n
Faulty or improperly
installed PCIe card.
Reseat the PCIe cards. See
"Expansion Cards" on
page 70. If the problem
persists, see "Getting Help"
on page 141.
PCIe Degraded Link
Width Error: Slot
n
Expected Link Width
is
n
Actual Link Width
is
n
Faulty or improperly
installed PCIe card in the
specified slot number.
Reseat the PCIe card in the
specified slot number. See
"Expansion Cards" on
page 70. If the problem
persists, see "Getting Help"
on page 141.
PCIe Training
Error: Embedded
Bus#
nn
/Dev#
nn
/Func
n
Faulty or improperly
installed PCIe card.
Reseat the PCIe cards. See
"Expansion Cards" on
page 70. If the problem
persists, see "Getting Help"
on page 141.
Table 1-6. System Messages (continued)
Message Causes Corrective Actions