Table 38. NvDIMM LED sequence (continued)
NvDIMM
RUN State System operating normally
System powered down, NVsave in progress
NVsave complete. Asserting EMMC_PWROFF_NOTIFY_N to BMC
V_12V_SW powered down. System in G3, waiting for AC power
Table 39. System board LED sequence
Error
LED7 LED6 LED5 LED4 LED3 LED2 LED1 Description
B B Config Error: CPU1 present? DIMMs OK? Install DBG JMPR1 to bypass
B B B B CPU IERR
CPU COMBINED MCERR
B B B B B B B Thermal Issue on CPU* or MEM
B B B B B Internal VR Issue on CPU*
B B AUX Power Failsafe
Table 40. Pfault or failsafe errors LED sequence
Pfault or Failsafe Errors
LED7 LED6 LED5 LED4 LED3 LED2 LED1 Description
* B 12V Failure
* B 5V BP0 Failure
* B 5V BP1 Failure
* B 5V BP2 Failure
* B 3.3V A Failure
* B 3.3V B Failure
* B 5V SW Failure
* B 1.05V SW Failure
* B CPU1 VCORE Failure
* B CPU2 VCORE Failure
* B CPU1 VCCIO Failure
* B CPU2 VCCIO Failure
* B CPU1 VSA Failure
* B CPU2 VSA Failure
* B CPU1 MEM012 VTT Failure
* B CPU1 MEM345 VTT Failure
* B CPU2 MEM012 VTT Failure
* B CPU2 MEM345 VTT Failure
* B CPU1 MEM012 VPP Failure
* B CPU1 MEM345 VPP Failure
* B CPU2 MEM012 VPP Failure
System diagnostics and indicator codes 27