EasyManua.ls Logo

Dell PowerVault LTO - Rack Mount Drive; Rack Mount Drive Specifications; Equipment Environment Specification

Dell PowerVault LTO
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table 17. Equipment environment specication
Equipment environment specication
Product power off
1
Dry-bulb temperature Relative humidity Maximum wet-bulb temperature
5 to 45°C (40 to 113°F) 8% to 80% RH 26°C (79°F)
Product operation (equipment is powered on)
Dry-bulb temperature Humidity range, non-
condensing
Maximum
dew point
temperature
4
Maximu
m wet-
bulb
tempera
ture
5
Maximu
m
elevatio
n
Allowab
le
2
Recom
mended
3
Maximu
m rate
of
change
Allowab
le
Recom
mended
Maximu
m rate
of
change
22°C (72°F) for
LTO 9
26°C
(79°F)
3050 m
(10,000
feet)
15 to
35°C
(59 to
95°F)
15 to
25°C
(59 to
77°F)
5°C/
hour
(9°F/
hour)
20% to
80% RH
20% to
50% RH
5% RH/
hour
with no
condens
ation
Note:
1. Product equipment is removed from the original shipping container and installed but not in use - for
example, during repair, maintenance, or upgrade.
2. Derate maximum dry-bulb temperature 1°C/300 m above 900 m (1.8°F/1,000 feet above 3,000
feet).
3. Derate maximum recommended dry-bulb temperature 1°C/300 m above 1,800 m (1.8°F/1,000 feet
above 6,000 feet).
4. Applies to LTO 9 drives
5. Applies to LTO drive generations 1 through 8.
Rack mount drive
Table 18. Rack mount drive
specications
Physical Specications
Width 48.3 cm (19.0 in)
Length 44.0 cm (17.32 in)
Height 9.0 cm (3.54 in)
Weight 10.23 kg (22.55 lb) Chassis empty
Power Requirements
AC line voltage 100 - 240 VAC
Line frequency 50 - 60 Hz, auto-ranging
Line current at 100 VAC 1.9 A
Line current at 240 VAC 0.8 A
Chapter 5. Specications 55

Table of Contents

Related product manuals