Gas connection
The refrigerator is designed to work on LPG gas, not natural gas or town gas.
Check that the pressure of supplied gas is 11 inches water column.
A suitable threaded coupling must be used to connect the gas pipe to the inlet.
Leakage test must be carried out after the connection is done.
Never use open flame to do leakage check.
AC 110-120V connection
The main AC terminal is inside the junction box. The cable must be secured
with clip tightly. Junction box cover is supplied separately.
After the main AC cable is connected, remember to secure the box cover on.
Note: The supply cord shall be H05VV-F and the minimum cross-sectional
area of conductors is 18AWG
DC12V connection
Follow the terminal indication to connect the DC power.
Do not reverse the positive and negative.
Please note that there two connectors for LED lamp
and DC heater separately.
Note: The minimum cross-sectional area of conductors for heater is 14AWG
The minimum cross-sectional area of conductors for lamp is 18AWG