12 of 81
In order to enable these PID functions it is necessary to use the Special M contacts
below.
A working example of such a PID function.can be found on our ftp site (Industrial
Automation Products\_Delta Application Guide\General information\Built-in PID
function).
Q How to read/write from/to the onboard PLC through Modbus TCP and Ethernet
IP?
A For the CMC-MOD01 and CMC-EIP01 cards this is supported starting with firmware
V1.08 (date code: W1852).
The drive firmware needs to be at least:
- CP2000 - V2.06 or higher.
- CFP2000 - V1.06 or higher.
- For C2000 this has not yet been released.
For the CMM-MOD01 and CMM-EIP01 cards this is supported starting with firmware
V1.04 (date code: W1850)
The drive firmware needs to be at least:
- MS300 - V1.08 or higher.
You can control the onboard PLC registers and contacts directly through station
address acc. to Pr09-35.