Q Can the digital inputs be operated from 24V?
A Yes, this is possible.
VFDxxxL21A or ...B: They have NPN inputs that are activated by shorting them to
ground.
VFDxxxL21D or ...E: They have PNP inputs. Either the internal 15V or an external
24V supply can be used.
Using internal 15V/30mA supply Using external 24V suppl
Q What does error code “23” mean?
A The fault codes have been extended; this info is not in the manual:
1
13
25
2
14
26
3
15
27
4
16
28
5
17
29
6
18
30
7
19
31
8
20
32
9
21
33
10
22
34
-Er. S/W Error
11
23
35
12
24
-
Q What is the difference in high and low torque setting on VFD-L1?
A High torque output is V
out
=V
command
+ 8% Rated input voltage.
Low torque output is V
out
=V
command
.