Q What are the available control modes in the different drives?
A
Series
C2000 CP2000
C200 * B E EL L
V/F OK OK OK OK OK OK OK
V/F+PG OK
OK OK OK
Sensorless
OK OK OK OK OK OK
Vector+PG
OK OK
FOC+PG for IM OK
OK
FOC+PG for PM
OK
TQC+PG for IM OK
OK
TQC+PG for PM
OK
FOC Sensorless
OK
OK
PM Sensorless
OK
OK
TQC Sensorless
OK
OK
Q What is the slip compensation parameter?
A The slip to be compensated in all our drives is calculated as follows:
where
Slip = slip to be compensated
I
L
= actual load current
I
NL
= no load current
I
FL
= full load current.
Rated_slip = the motor rated slip in Hz
Slip_compensation = slip compensation factor
In some drives the slip compensation is
The setting range is in that case 0.0~10.0 and the rated slip cannot be entered
separately
In some drives the slip compensation is
The setting range is in that case 0.0~3.0 and the rated slip can be entered separately