9 of 81
The maximum cable section that these terminals can accommodate is 12AWG or
4mm
2
.
The minimum cable section that these terminals can accommodate is 18AWG or
0.75mm
2
.
Because the terminals of a frame size are always the same, it means that the power
terminals of any ME300 in Frame B can accommodate a wire section between
0.75~4mm
2
.
The actual wire section, that should be used, depends on the application: Current and
Cable length.
Very long cables or cables for higher current should be thicker
(but in this case not >4mm
2
).
Short cables or cable for lower current can be thinner
(but in this case not <0.75mm
2
).
If you have to or want to use another cable section, please use lugs or ferrules.
The same applies to other frame sizes and Delta drives.