2/ Receiver installation
Recommendations
IMPORTANT: the control wires are not insulat-
ed from the mains power supply. All connected
equipment must be marked CE and meet the
requirements of the low voltage devices as well as
assembly recommendations.
Local control wires can be extended up to 10 m
(separate from the 230 V).
The roller shutter high and low stops must be set
before the receiver is installed.
10A circuit breaker required.
Use an electrically isolated tool to
perform the actions on the receiver