Chapter 7 Servo Parameters|ASDA-A&A+ Series
Revision April 2009 7-15
Torque Control
Control
Mode
Parameter Name Function Default Unit
Pt Pr S T
Related
Section of
User
Manual
P1-01
CTL Control Mode and Output Direction 0
pulse
r/min
N-m
{ { { {
6.1
P1-02
PSTL Speed and Torque Limit 0 N/A
{ { { {
6.6
P1-46
GR3 Encoder Output Pulse Number 1 pulse
{ { { {
---
P1-55 MSPD Maximum Speed Limit
rated
speed
r/min
{ { { {
---
1st ~ 3rd Speed Command
P1-09
~ P1-11
SP1 ~
3
1st ~ 3rd Speed Limit
100 ~
300
r/min
{ {
6.6.1
1st ~ 3rd Torque Command
P1-12
~ P1-14
TQ1 ~
3
1st ~ 3rd Torque Limit
100 %
{ { { {
6.4.1
P1-40
VCM
Max. Analog Speed Command or
Limit
rated
speed
r/min
{ {
---
P1-41
TCM
Max. Analog Torque Command or
Limit
100 %
{ { { {
6.4.4
Explanation of symbols (marked after parameter)
() Read-only register.
() Parameter cannot be set when Servo On (when the servo drive is enabled).
() Parameter is effective only after the servo drive is restarted (after switching power off and on).
() Parameter setting values are not retained when power is off.
Call 1(800)985-6929 for Sales
deltaacdrives.com
sales@deltaacdrives.com
Call 1(800)985-6929 for Sales
deltaacdrives.com
sales@deltaacdrives.com

Table of Contents

Other manuals for Delta Electronics ASDA-A Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta Electronics ASDA-A Series and is the answer not in the manual?

Delta Electronics ASDA-A Series Specifications

General IconGeneral
BrandDelta Electronics
ModelASDA-A Series
CategoryServo Drives
LanguageEnglish

Related product manuals