Questions and Answers

  • E
    emily38Sep 23, 2025
    What should I do if the emergency stop is activated on my Delta Electronics Servo Drive?
    • S
      Steven PriceSep 23, 2025
      If the emergency stop is activated on your Delta Electronics Servo Drive, it's because the emergency stop switch is disabled. Activate the emergency stop switch.
  • U
    uleeAug 23, 2025
    What causes regeneration error in Delta Electronics ASDA-A?
    • A
      Austin ClayAug 25, 2025
      A regeneration error in Delta Electronics Servo Drives can occur due to several reasons. Check if the regenerative resistor is properly connected and reconnect it if necessary. If the regenerative switch transistor is faulty, return the unit to the distributor or manufacturer. A parameter setting error can also cause this, so correctly reset the parameters.
  • J
    Jennifer HoganAug 25, 2025
    What causes an overspeed error on Delta Electronics ASDA-A?
    • G
      Gary DavisAug 26, 2025
      An overspeed error on Delta Electronics Servo Drives can be triggered by a couple of things. First, the speed input command might not be stable, exhibiting too much fluctuation. To address this, ensure the input command frequency is stable and activate the filter function. Second, the over-speed parameter setting might be defective, so correctly set the over-speed parameter setting again.
  • S
    sgordonAug 27, 2025
    What causes a serial communication error in Delta Electronics ASDA-A Servo Drives?
    • S
      Sonya GravesAug 27, 2025
      A serial communication error in Delta Electronics Servo Drives can stem from several issues. The communication parameter setting might not be correct, so ensure the parameter setting value is set correctly. Also, the communication address might be incorrect, so make sure the communication address is set correctly. Finally, the communication setting value might be incorrect, so verify that the communication setting value is correct.
  • M
    Michael MendozaAug 27, 2025
    What to do if my Delta Electronics Servo Drive shows an adjustment error?
    • R
      Ronald ParkerAug 28, 2025
      If your Delta Electronics Servo Drive shows an adjustment error, it could be because the analog input contact does not correctly return to zero. Correctly ground the analog input contact. If the error persists after resetting the power supply, the detection device may be damaged, contact the distributor for assistance or return to manufacturer.
  • J
    Jessica MendozaSep 17, 2025
    How do I resolve a forward limit switch error on my Delta Electronics Servo Drive?
    • C
      connie04Sep 17, 2025
      A forward limit switch error on your Delta Electronics Servo Drive can occur if the forward limit switch is disabled, so activate it. It can also be caused by an unstable servo system, so modify the parameter setting and estimate motor capacity again.
  • M
    Michael HernandezSep 14, 2025
    What does it mean when my Delta Electronics Servo Drive displays 'excessive deviation'?
    • S
      Steven HuertaSep 14, 2025
      When your Delta Electronics Servo Drive displays 'excessive deviation', it indicates that the maximum deviation parameter setting is too small, so increase the setting value. It could also mean that the gain value is too small, so correctly adjust the gain value. Another possibility is that the torque limit is too low, so correctly adjust the torque limit value. Finally, there might be an overload, so reduce the external applied load or re-estimate the motor capacity.
  • A
    acunninghamSep 15, 2025
    How do I fix a reverse limit switch error on my Delta Electronics Servo Drive?
    • M
      Michael OrtegaSep 16, 2025
      A reverse limit switch error on your Delta Electronics Servo Drive can be due to the reverse limit switch being disabled, so activate it. It can also happen if the servo system is not stable, so modify the parameter setting and estimate motor capacity again.
  • E
    Elijah ShawSep 6, 2025
    Why is my Delta Electronics Servo Drive showing an overvoltage error?
    • J
      Jonathan NavarroSep 6, 2025
      An overvoltage error on your Delta Electronics Servo Drive can occur if the main circuit voltage exceeds its maximum allowable value, or if there's an input power error due to incorrect power input. To resolve this, use the correct power supply or a serial stabilizer.
  • M
    munozkimSep 3, 2025
    What causes a DSP communication error in Delta Electronics ASDA-A?
    • D
      David JacksonSep 3, 2025
      A DSP communication error in Delta Electronics Servo Drives is caused by a control power error. If the error does not clear after resetting the power supply, contact the distributor for assistance or return to manufacturer.

Delta Electronics ASDA-A Series Specifications

General IconGeneral
SeriesASDA-A
CategoryServo Drives
Control ModesPosition, Speed, Torque
FeedbackIncremental encoder, Absolute encoder
Protection ClassIP20
Communication InterfaceRS-485
Protection FeaturesOver-voltage, Over-current, Overtemperature
Operating Temperature0°C to 50°C
Storage Temperature-20°C to 65°C
Shock Resistance11ms