EasyManua.ls Logo

Delta Electronics ASDA-A Series - Page 206

Delta Electronics ASDA-A Series
383 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 7 Servo Parameters|ASDA-A&A+ Series
Revision April 2009 7-43
P1 - 46
GR3 Encoder Output Pulse Number Communication Addr.: 012EH
Default: 1 Related Section: N/A
Applicable Control Mode: ALL
Unit: pulse
Range: 1 ~ 125 (with B=0)
10020 ~ 12500 (with B=1)
Settings:
A
B
This parameter is used to set the pulse numbers of encoder outputs per motor revolution.
ASDA-A series:
A: Range of the pulse numbers or the pulse dividing ratio of the encoder outputs
Range of the setting value: 1 ~ 125 (with B=0) or 20 ~ 2500 (with B=1)
B: Pulse dividing ratio function selection
When B=0, the setting value A represents the pulse dividing ratio, which is equal to 2500/A.
At this time, the range of the setting value A is 1 ~ 125.
For example:
If A=2 and B=0, i.e. P1-46 is set to 2, the pulse dividing ratio is equal to 2500/2 = 1250.
It indicates that the pulse numbers of encoder outputs per motor revolution = 1250 pulses
(The encoder will output 1250 pulses per motor revolution)
If A=5 and B=0, i.e. P1-46 is set to 5, the pulse dividing ratio is equal to 2500/5 = 500.
It indicates that the pulse numbers of encoder outputs per motor revolution = 500 pulses
(The encoder will output 500 pulses per motor revolution)
When B=1, the setting value A directly represents the pulse numbers of encoder outputs per
motor revolution. At this time, the range of the setting value A is 20 ~ 2500.
If A=1250 and B=1, i.e. P1-46 is set to 11250, the pulse numbers of encoder outputs per
motor revolution = 1250 pulses (The encoder will output 1250 pulses per motor revolution)
If A=500 and B=1, i.e. P1-46 is set to 10500, the pulse numbers of encoder outputs per
motor revolution = 500 pulses (The encoder will output 500 pulses per motor revolution)
ASDA-A+ series:
A: Range of the pulse numbers or the pulse dividing ratio of the encoder outputs
Range of the setting value: 1 ~ 125 (with B=0) or 20 ~ 2500 (with B=1)
B: Pulse dividing ratio function selection
When B=0, the range of the setting value A is 1 ~ 125, the pulse numbers of encoder outputs
per motor revolution =
125)A(1
2
2
A
2500
61P1
7
×
Call 1(800)985-6929 for Sales
deltaacdrives.com
sales@deltaacdrives.com
Call 1(800)985-6929 for Sales
deltaacdrives.com
sales@deltaacdrives.com

Table of Contents

Other manuals for Delta Electronics ASDA-A Series

Related product manuals