EasyManua.ls Logo

Delta Electronics ASDA-A Series - Page 246

Delta Electronics ASDA-A Series
383 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 7 Servo Parameters|ASDA-A&A+ Series
Revision April 2009 7-83
P4 - 09
MOT Output Status Display Communication Addr.: 0409H
Default: 0 Related Section:
Applicable Control Mode: ALL Section 4.4.6
Unit: N/A
Range: 0~0x1F
Settings:
External Control: Display the status of DO output signal
Communication Control: Read the status of output signal
The status of DO signal, please refer to P2-18 ~ P2-22.
P4 - 10
CEN Adjustment Function Communication Addr.: 040AH
Default: 0 Related Section: N/A
Applicable Control Mode: ALL
Unit: N/A
Range: 0~6
Settings:
0: Reserved
1: Execute analog speed input drift adjustment
2: Execute analog torque input drift adjustment
3: Execute current detector (V phase) drift adjustment
4: Execute current detector (W phase) drift adjustment
5: Execute drift adjustment of the above 1~4
6: Execute IGBT NTC calibration
This adjustment function is enabled after parameter P2-08 is set to 20.
When executing any adjustment, the external wiring connected to analog speed or torque must
be removed and the servo system should be off (Servo off).