DC POWER SUPPLIES
DELTA ELEKTRONIKA B.V.
Vissersdijk 4, 4301 ND
Zierikzee, the Netherlands
www.DeltaPowerSupplies.com
Tel. +31 111 413656
SM3000-se ries
PROD UCT MAN UAL
Con tents:
1 - Datasheet
2 - Safety Instructions
3 - Descriptions
4 - Operating,Trouble Shooting, Calibration
5 - EC Declaration of Conformity
SM 15 - 200 D
SM 30 - 100 D
SM 45 - 70 D
SM 70 - 45 D
SM 120 - 25 D
SM 300 - 10 D
Question and Answer IconNeed help?

Do you have a question about the Delta Elektronika SM30-100D and is the answer not in the manual?

Delta Elektronika SM30-100D Specifications

General IconGeneral
Output Voltage0 - 30 V
Output Current0 - 100 A
Power Rating3000 W
TypeProgrammable DC Power Supply
Efficiency> 90%
CoolingFan
ProtectionsOvervoltage, Overcurrent, Overtemperature

Summary

Safety Instructions

General Safety Precautions

Covers essential safety warnings, grounding, connection, fuses, ratings, live circuits, and part substitution guidelines.

Grounding and Connection Requirements

Details installation category, grounding of AC and DC terminals, and mains connection procedures.

Product Descriptions

Output Characteristics

Describes the output modes (constant voltage/current) and overload protection features.

Product Descriptions (Continued)

Programming Inputs and Communication

Details analog and IEEE488/RS232 programming capabilities for voltage and current control.

Product Descriptions (Continued)

Series and Parallel Operation

Covers allowed series operation up to 600V and parallel operation without limitations.

Master/Slave Operation Modes

Explains Master/Slave features for forming larger units and programming via master.

Remote Sensing and OVP

Details remote sensing for constant load voltage and the Over Voltage Protector (OVP) function.

Operating Manual

First Time Operation

Guides on initial unit setup, cable connections, potentiometers, and OVP setting.

Analog Programming

Instructions for programming voltage and current using external analog sources.

IEEE488 / RS232 Programming

Details programming and status reading via IEEE488 or RS232 interfaces.

Operating Manual (Continued)

Remote Shutdown and Over Current Trip

Explains controlling output via remote shutdown and implementing an over current trip.

Master/Slave Series Operation

Instructions for connecting units in series using the Master/Slave Series Adapter.

Trouble Shooting

General Troubleshooting Advice

Provides general guidance for contacting support and preparing for repairs.

Trouble Shooting (Continued)

Serious Failure Checklist

A checklist for diagnosing serious failures, including checking fuses and output diodes.

EC Declaration

Declaration of Conformity for SM3000-series

Declaration of conformity for Electromagnetic Compatibility and Electrical Safety according to EU directives.