ASDA-M         Chapter 8 Parameters 
Revision December, 2014                                  8-111 
 
Settings: 
If users do not know how to set P2-54~P2-56, setting the 
bandwidth of synchronous control value will do since the value 
will correspond to P2-54~P2-56. The bigger the bandwidth of 
synchronous control value is, the better the synchronous effect 
will be. When increasing the bandwidth of speed loop and 
synchronous control, pay special attention to the response of 
P2-25 which should be faster than the setting of the both 
bandwidth.  
(Firmware, V1.005 sub00 will be provided soon) 
 
P2-58    GTRY  Gantry Function 
Address: 0274H 
0275H 
 
Parameter 
Attribute: 
Parameter for individual axis 
Related Section: - 
 
Operational
 Interface: 
Panel / Software  Communication 
 
Default: 
X Axis: 0000h 
Y Axis: 0010h 
Z Axis: 0020h 
 
Control 
Mode: 
ALL 
 
Unit: 
- 
 
Range: 
0000h ~ 0x1021 
 
Data Size: 
16bit 
 
Format: 