    Deborah SnyderAug 31, 2025
    What causes overspeed in Delta ASD-A2-4543 Servo Drives?
    • B
      browntracyAug 31, 2025
      Overspeed in Delta Servo Drives can be triggered by: * Unstable speed input command (too much fluctuation). If this is the case, ensure that input command frequency is stable (not fluctuate too much) and activate filter function. * Defective over-speed parameter setting. If this is the case, correctly set over-speed parameter setting (P2-34).
  • K
    Kerri GonzalesAug 25, 2025
    What causes undervoltage in Delta Servo Drives and how to fix it?
    • D
      Dawn NewmanAug 25, 2025
      Undervoltage in Delta Servo Drives can be caused by: * The main circuit voltage being below its minimum specified value. If this is the case, reconfirm voltage wiring. * No input voltage at the main circuit. If this is the case, reconfirm the power switch. * Incorrect power input. If this is the case, use the correct power supply, a stabilizing power supply, or a series transformer.
  • M
    Molly HarrisSep 14, 2025
    What to do if Delta ASD-A2-4543 show Warning of servo drive function overload?
    • R
      rjacksonSep 14, 2025
      If your Delta Servo Drives are showing a warning of servo drive function overload, set P2-66 Bit4 to 1 and then re-power on the servo drive.
  • J
    joshuarileySep 23, 2025
    How to resolve Error occurs when writing CANopen PDO via EEPROM in Delta ASD-A2-4543?
    • A
      Alexandra MurphySep 23, 2025
      To resolve error occurs when writing CANopen PDO via EEPROM in Delta Servo Drives, when an error occurs when saving the current value into ROM, use NMT: Reset node or 0x6040.Fault Reset.
  • M
    Melissa WardSep 9, 2025
    What to do if Delta Servo Drives show abnormal pulse command?
    • J
      Jonathan WilsonSep 9, 2025
      If your Delta Servo Drives are showing an abnormal pulse command, it could be because the pulse command frequency is higher than the rated input frequency. Correctly set the input pulse frequency.
  • P
    pottermichelleSep 23, 2025
    How to fix An error occurs when loading CANopen data in Delta ASD-A2-4543 Servo Drives?
    • S
      Scott MclaughlinSep 23, 2025
      To fix an error occurs when loading CANopen data in Delta Servo Drives, when an error occurs when loading data via EEPROM, use DI.ARST, CANopen 0x1011 Restore default parameter.
  • D
    Danielle WilliamsAug 29, 2025
    What to do if index error occurs when accessing CANopen object on Delta Servo Drives?
    • S
      Stephanie WoodwardAug 29, 2025
      If the specified Index in the message does not exist, NMT Maser send “Reset node“ command to its slave or reset the fault by sending the control word (0x6040) through CAN communication (the value of CANopen object 0x6040 should be reset).
  • S
    Sherry JonesSep 16, 2025
    How to resolve Encoder does not complete the command which is issued by servo drive in Delta ASD-A2-4543 Servo Drives?
    • K
      Kevin GarciaSep 16, 2025
      If your Delta Servo Drives are showing that the encoder does not complete the command which is issued by servo drive because servo drive has not completely written barcode into encoder or the encoder does not complete the command issued by servo drive, correct the wiring.
  • A
    Amber PadillaSep 18, 2025
    How to fix Data range error occurs when accessing CANopen PDO in Delta ASD-A2-4543?
    • N
      nicholasharperSep 18, 2025
      To fix data range error occurs when accessing CANopen PDO in Delta Servo Drives, when the data value in the message is over the range of the specified object, use NMT: Reset node or 0x6040.Fault Reset.
  • G
    Glenn JacksonAug 27, 2025
    What causes CANbus error on Delta ASD-A2-4543 Servo Drives?
    • A
      Adrian PowellAug 27, 2025
      A CANbus error on Delta Servo Drives is caused by CANbus off or Error Rx/Tx Counter exceeding 128. NMT Maser send “Reset node“ command to its slave or restart the servo drive.