ASDA-M Chapter 3 Wiring
Revision December, 2014 3-35
C4-2: High-speed pulse input (Line driver) can only apply to 5V power. Do not apply to
24V power.
The high-speed pulse input interface of the servo drive is not the
isolated interface. In order to reduce the interference of the noise, it is
suggested that the terminal ground of the controller and the servo
drive should be connected to each other.