Delta C200 Series - Chapter 6 Control Terminals; Remove the cover for wiring

Delta C200 Series
363 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 6 Control Terminals|C200 Series
6-1
Chapter 6 Control Terminals
Please remove the top cover before wiring the multi-function input and output terminals,
The drive appearances shown in the figures are for reference only, a real drive may look different.
Remove the cover for wiring.
Frame A0&A
Loosen the screws and press the tabs on both sides to remove the cover.
Screw torque:
Frame A0 : 6~8Kg-cm [5.21~6.94lb-in.]
Frame A : 10~12Kg-cm [8.68~10.4lb-in.]
Frame A0 Remove the Conduit-Box
1. Remove the cover, and then loosen the screws
of wiring guard. Keep those screws for future
use.
NOTE: C200-21 /-21M doesn’t have a plastic
circuit board.
2. Use spare screws to fasten the Conduit box.
Screw torque: 8-10Kg-cm(6.9-8.7lb-in.)