EasyManua.ls Logo

Delta VFD037CB43A-20 User Manual

Delta VFD037CB43A-20
363 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
- &(

7KLVZHEYHUVLRQZLOOEHLQFOXGHGLQWKHXSFRPLQJ
RIILFLDOUHOHDVHGGRFXPHQW&(
Call 1(800)985-6929 for Sales
deltaacdrives.com
sales@deltaacdrives.com
Call 1(800)985-6929 for Sales
deltaacdrives.com
sales@deltaacdrives.com
Question and Answer IconNeed help?

Do you have a question about the Delta VFD037CB43A-20 and is the answer not in the manual?

Delta VFD037CB43A-20 Specifications

General IconGeneral
BrandDelta
ModelVFD037CB43A-20
CategoryDesktop
LanguageEnglish

Summary

Preface

PLEASE READ PRIOR TO INSTALLATION FOR SAFETY.

Essential safety guidelines before connecting power to the AC motor drive, including DANGER and CAUTION notes.

Chapter 3 How to Select the Right AC Motor Drive

3-1 Capacity Formulas

Formulas and guidelines for calculating the required capacity of AC motor drives for single and multiple motor applications.

3-2 General Precaution

Important precautions for selecting and using AC motor drives, including transformer connections, motor configurations, and error handling.

3-3 How to Choose a Suitable Motor

Guidelines for selecting suitable motors, including standard and special motor types, and considerations for vibration and noise.

Chapter 4 Wiring

Precautions before wiring

Essential precautions to follow before wiring the AC motor drive, including power application, grounding, and terminal fastening.

DANGER

Critical safety warnings regarding power disconnection, hazardous voltages in capacitors, and handling sensitive MOS components.

CAUTION

Safety cautions related to wiring practices, including selecting compliant wires and checking connections.

Wiring Diagram

Detailed wiring diagram for 1-phase/3-phase power, main circuit, control terminals, and communication interfaces.

Chapter 5 Main Circuit Terminals

Main Circuit Diagram

Diagrams showing the main circuit connections for Frame A0 and Frame A AC motor drives.

Main power terminals

Precautions for main power terminals, including connection to transformers, magnetic contactors, GFCI, and shielded wires.

Output terminals for main circuit

Instructions for output terminals, including filter installation and motor insulation requirements.

Chapter 6 Control Terminals

Control Terminal the sketch map

Schematic diagrams illustrating control terminals for Frame A0 and Frame A.

Terminals Terminal Function Factory Setting (NPN mode)

Table detailing terminals, their functions, and factory settings for NPN mode.

Chapter 7 Optional Accessories

All Brake Resistors and Brake Units Used in AC Motor Drives

Table detailing brake resistors and units for 230V 1-phase, 230V 3-phase, and 460V applications, including braking torque and current specifications.

EMI Filter Installation

Guidelines for installing EMI filters correctly to eliminate interference, including mounting, wiring, and grounding precautions.

Digital Keypad

Description of Digital Keypad functions, including Start/Stop, Operation Direction, ENTER, and ESC keys.

USB/RS-485 Communication Interface IFD6530

Details of the IFD6530 converter, including warnings, introduction, specifications, and RJ-45 pin definition.

Chapter 8 Specification

General Specifications

General specifications for AC motor drives, including control method, speed response, torque characteristics, and protection features.

Environment for Operation, Storage and Transportation

Environmental requirements for operating, storing, and transporting AC motor drives, including temperature, humidity, pollution level, and altitude.

Chapter 9 Digital Keypad

Description of the Digital Keypad KPE-LE02

Detailed description of the KPE-LE02 digital keypad, including its keys, LED display, and functions.

How to Operate the Digital Keypad

Step-by-step guide on operating the digital keypad, including setting mode, shifting data, setting direction, and setting PLC mode.

Chapter 10 Summary of Parameter Settings

01 Basic Parameters

Summary of basic parameters, including maximum/minimum operation frequency, voltage, and mid-point settings.

Chapter 11 Description of Parameter Settings

00 Drive Parameters

Detailed descriptions of drive parameters, including identity code, rated current, parameter reset, start-up display, and multi-function display content.

01 Basic Parameters

Detailed description of basic parameters, including maximum/minimum output frequency, voltage, and mid-point settings.

02 Digital Input/Output Parameters

Summary of digital input/output parameters, including operation control modes and multi-function input/output command settings.

03 Analog Input/Output Parameters

Summary of analog input/output parameters, including input selection for AVI, ACI, AUI and their bias settings.

05 Motor Parameters

Summary of motor parameters, including auto-tuning for induction and permanent magnet motors, and detailed specifications.

06 Protection Parameters

Summary of protection parameters, including low/over-voltage levels, over-current and over-torque detection settings, and thermal relay selections.

08 High-function PID Parameters

Summary of high-function PID parameters, including input terminals, proportional gain, integral time, and derivative control.

09 Communication Parameters

Summary of communication parameters for COM1, including address, transmission speed, fault treatment, and protocol settings.

10 Speed Feedback Control Parameters

Summary of speed feedback control parameters, including encoder settings, stall level, slip range, and FOC/TQC function control.

Chapter 12 Warning Codes

Display Fault code

Table of fault codes displayed on KPE-LE02 and KPC-CC01, with descriptions, CANopen fault codes, and fault register bits.

Chapter 13 CANopen Overview

13.3 How to Control by CANopen

Steps for controlling AC motor drives via CANopen, including control mode selection, hardware wiring, and parameter settings.

Chapter 14 PLC Function

14.2 Precautions for Using PLC Functions

Precautions for using PLC functions, covering default settings, host controller configuration, program upload/download, parameter writing limits, and display modes.

14.3 Start-up

Steps for PLC execution, including setting the mode, connecting to the computer, running the program, and optional accessories.

14.4 Ladder Diagram

Explanation of ladder diagram structure, symbols, and basic motions used in PLC programming.

14.4.4 The Example for Designing Basic Program

Examples of designing basic PLC programs, including start/stop/latching circuits, SET/RST commands, and common control circuits.

14.5 PLC Devices Function

Description of PLC devices functions, including Control Method, I/O Processing Method, Execution Speed, Program Language, Capacity, Commands, and Input/Output Contacts.

Chapter 15 Suggestions and Error Corrections for Standard AC Motor Drives

15-2 Greasy Dirt Problem

Explanation of greasy dirt problems in industrial environments and their potential damages to drives, along with solutions.

15-3 Fiber Dust Problem

Description of fiber dust problems, particularly in textile industries, detailing potential damages and solutions.

15-4 Erosion Problem

Explanation of erosion problems caused by fluid ingress into drives, detailing potential damages and solutions.

15-5 Industrial Dust Problem

Description of industrial dust problems, potential damages from dust accumulation, and recommended solutions.

15-6 Wiring and Installation Problem

Common wiring and installation problems, such as loose screws and internal component damage, with solutions and recommendations.

15-7 Multi-function Input/Output Terminals Problem

Explanation of errors related to multi-function input/output terminals due to overuse or exceeding specifications, with recommended solutions.

Related product manuals