Chapter 10 Summary of Parameter Settings|C200 Series
10-26
09 Communication Parameters
Parameter Explanation Settings
Factory
Setting
09-00
COM1 Communication
Address
1~254 1
09-01
COM1 Transmission
Speed
4.8~115.2Kbps 19.2
09-02
COM1 Transmission Fault
Treatment
0: Warn and continue operation
1: Warn and ramp to stop
2: Warn and coast to stop
3: No warning and continue operation
3
09-03 COM1 Time-out Detection 0.0~100.0 sec. 0.0
09-04
COM1 Communication
Protocol
0: 7N1 (ASCII)
1: 7N2 (ASCII)
2: 7E1 (ASCII)
3: 7O1 (ASCII)
4: 7E2 (ASCII)
5: 7O2 (ASCII)
6: 8N1 (ASCII)
7: 8N2 (ASCII)
8: 8E1 (ASCII)
9: 8O1 (ASCII)
10: 8E2 (ASCII)
11: 8O2 (ASCII)
12: 8N1 (RTU)
13: 8N2 (RTU)
14: 8E1 (RTU)
15: 8O1 (RTU)
16: 8E2 (RTU)
17: 8O2 (RTU)
13
09-05
~
09-08
Reserved
09-09 Response Delay Time 0.0~200.0ms 2.0
09-10
Main Frequency of the
Communication
0.00~600.00Hz 60.00
09-11 Block Transfer 1 0~65535 0
09-12 Block Transfer 2 0~65535 0
09-13 Block Transfer 3 0~65535 0
09-14 Block Transfer 4 0~65535 0
09-15 Block Transfer 5 0~65535 0
09-16 Block Transfer 6 0~65535 0
09-17 Block Transfer 7 0~65535 0
09-18 Block Transfer 8 0~65535 0
09-19 Block Transfer 9 0~65535 0
09-20 Block Transfer 10 0~65535 0
09-21 Block Transfer 11 0~65535 0
09-22 Block Transfer 12 0~65535 0
09-23 Block Transfer 13 0~65535 0
09-24 Block Transfer 14 0~65535 0
09-25 Block Transfer 15 0~65535 0
09-26 Block Transfer 16 0~65535 0