User and Installation Manual, DE212 GLOBAL
DELTA RC AS Page 8 of 36
Document 02743
2.3 CHANGING THE FUNCTION OF THE RECEIVER UNIT BY SW2.
The function of the receiver unit can be changed according to operational requirements.
The following can be changed:
SW2-1: Timed or no timed Deadman. ON is activated.
SW2-2: Simultaneous or no simultaneous operation of the extra function, connection P1-3 when the
Deadman is activated.
SW2-3: External override, active or off.
SW2-4: Differential Pressure Switch on or off.
Standard factory setting of SW2 switches:
To change the settings:
1. Set the function switch, SW2 to the desired position
2. Take out the fuse, F1.
3. Press the receiver front button CODE while replacing the fuse. Press the CODE button for about 3
seconds, then the function is changed according to settings.
4. NOTE: SW2-2 must ALWAYS be set back to OFF after settings are changed.
SW2 Switch for function selection
NOTE: The connector for external override and STOP is normally not installed
This functions must be specified when ordering, see page 7.
2
3
4
1
1. Deadman timer enabled, 2 min timer (Default ON)
2. Simultaneous operation of extra function (Default OFF)
3. Deadman override input disabled (Default ON)
4. DP Enabled (Default ON)
OFF
ON