DVP-ES2/EX2/SS2/SA2/SX2/SE&TP Operation Manual - Programming
3-86
API
Mnemonic Operands Function
Controllers
ES2/EX2/
EC5
SS2
SA2
SE
SX2
27 WOR P
Logical Word OR
Type
OP
Bit Devices Word devices Program Steps
X Y M S K H KnX
KnY
KnM
KnS
T C D E F
WOR, WORP: 7 steps
S
1
*
*
*
*
*
*
*
*
*
*
*
S
2
*
*
*
*
*
*
*
*
*
*
*
D
*
*
*
*
*
*
*
*
PULSE
16-bit
32-bit
ES2/EX2
/EC5
SS2
SA2
SE
SX2
ES2/EX2
/EC5
SS2
SA2
SE
SX2
ES2/EX2
/EC5
SS2
SA2
SE
SX2
Operands:
S
1
: Source data device 1 S
2
: Source data device 2 D: Operation result
Explanations:
1. This instruction conducts logical OR operation of S
1
and S
2
in 16-bit mode and stores the
result in D.
2. For 32-bit operation please refer to DOR instruction.
Program Example:
When X0 = ON, the 16-bit data source D0 and D2 are analyzed and the result of the logical OR is
stored in D4.
X0
WOR
D0
D2 D4
0 0 1 11 1 1 1
0 0 0 0 0 01 1 1 1
0 0 0 0
1 1 1
WOR
b15 b00
0 0 0 0 0 01 1
0 1 1 1 0 1
1 1 1 1 1 1 1 1 1
Before
execution
After
execution
1
D0
D2
D4